close
close
1.866.451.2257

9am-5pm M-F

Request A Quote or Call for Discounted Pricing!
sidebar:
click to zoom in

FLIR A320 Thermal Imaging Camera (A3xx series)

$15,250.00 - $21,625.00
SKU:
42701-120x
UPC:
8.45E+11
Condition:
New
Availability:
Call for Best Pricing and Customization
Weight:
1.00 LBS
Shipping:
Free Shipping
Free U.S. Shipping:
Over $100
FDA Approved:
K033967
Request A Quote
  • Customer Success

    We know our products!

  • Technical Specialists

    Product and System Support

  • Guaranteed Fit

    Right tool for the job

  • Free US Shipping

    Purchases Over $100

FLIR A320 Thermal Imaging Camera (A3xx series)

$15,250.00 - $21,625.00

FLIR A320 Thermal Imaging Camera (A3xx series)

$15,250.00 - $21,625.00

FLIR A320 Tempscreen (Can be used for elevated body temperature) 

FDA Approved K033967

The FLIR A320 Tempscreen camera is preconfigured for monitoring individuals to find temperature deviations or elevated skin temperature, including difference temperature alarms with a dynamically updated reference temperature. This temperature measurement solution offers built-in analysis, alarm functionality, and autonomous communication using standard protocols. The FLIR A320 Tempscreen also has features and functions to build distributed single- or multi-camera solutions utilizing standard Ethernet hardware and software protocols.

  • Industry-Standard Communication Protocols

    The A320 Tempscreen is Ethernet/IP and Modbus TCP compliant, so it can easily share analysis and alarm results to a programmable logic controller (PLC).

  • Wide Range of Alarm and Analysis Options

    Offering extensive analysis and alarm functionality, including a dynamic updated reference temperature (visualized by the isotherm).

  • Multi-Camera Software Included

    The A320 Tempscreen comes complete with FLIR IP Config and a FLIR IR Monitor for multi-camera configurations.

Features:

  • Screening: difference temperature alarm with a dynamic updated reference temperature (visualized by the isotherm).
  • Built-in extensive analysis functionality.
  • Extensive alarm functionality, as a function of analysis and more.
  • On schedule: file sending (FTP) or e-mail (SMTP) of analysis results or images.
  • On alarms: file sending (FTP) or e-mail (SMTP) of analysis results or images.
  • MPEG-4 streaming.
  • PoE (Power over Ethernet).
  • Built-in web server.
  • General purpose I/O.
  • 100 Mbps Ethernet (100 m cable, wireless, fiber, etc.).
  • Synchronization through SNTP.
  • Composite video output.
  • Multi-camera utility software: FLIR IP Config and FLIR IR Monitor included.
  • Open and well-described TCP/IP protocol for control and set-up.
  • 16-bit 320 × 240 pixel images semi-real time, signal and temperature linear.
  • Lenses: 25° included, 15° and 45° optional.
 
Specifications
Overview
Accuracy
±2°C (±3.6°F) or ±2% of reading
Alarm Functions
6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Alarm Output
Digital Out, log, store image, file sending (ftp), email (SMTP), notification
Base Mounting
2 × M4 thread mounting holes (on three sides)
Detector Type
Focal Plane Array (FPA), uncooled microbolometer
Difference Temperature
Delta temperature between measurement functions or reference temperature
Field of view (FOV)
25° × 18.8°
Focal Length
18 mm (0.7 in.)
Housing material
Aluminum
IR Resolution
320 × 240 pixels
Object Temperature Range
–20°C to 120°C (–4°F to 248°F) 0 °C to 350°C (32°F to 662°F)
Size (L x W x H)
170 × 70 × 70 mm (6.7 × 2.8 × 2.8 in.)
Thermal Sensitivity/NETD
<0.05°C @ 30°C (86°F) / 50 mK
Weight
0.7 kg (1.54 lb.)
Zoom
1–8× continuous, digital, interpolating zooming on images
Contents
Cardboard box, Infrared camera with lens, Ethernet cable, Mains cable, Power cable - pig-tailed, Power supply, Printed documentation, Utility CD-ROM
FLIR Screen-EST Mode
Yes
Accuracy [Drift] in Screen-EST Mode
±0.5°C (±0.9°F) accuracy at 37°C (98.6°F) with reference
Connections & Communications
Digital I/O connector type
6-pole jackable screw terminal
Digital I/O isolation voltage
500 VRMS
Digital I/O supply voltage
6–24 VDC, max. 200 mA
Digital input purpose
Image tag (start/stop/general), Input ext. device (programmatically read)
Digital Inputs
2 opto-isolated, 10–30 VDC
Digital Output Purpose
As function of ALARM, Output to ext. device (programmatically set)
Digital Outputs
2 opto-isolated, ON = supply (max. 100 mA), OFF = open
Ethernet
Control, result and image
Ethernet Communication
TCP/IP socket-based FLIR proprietary
Ethernet Connector Type
RJ-45
Ethernet Image Streaming
16-bit 320 × 240 pixels @ 4.5 Hz - Radiometric
Ethernet Power
Power over Ethernet, PoE IEEE 802.3af class 0
Ethernet Protocols
Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet Standard
IEEE 802.3
Ethernet Type
100 Mbps
Ethernet Video Streaming
MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
Storage Media
Built-in memory for image storage
Video Out
Composite video output, PAL and NTSC compatible
Video Connector Type
Standard BNC connector
Environmental
Atmospheric transmission correction
Automatic, based on inputs for distance, atmospheric temperature and relative humidity
EMC
•EN 61000-6-2 (Immunity) •EN 61000-6-3 (Emission) •FCC 47 CFR Part 15 Class B (Emission)
Emissivity Correction
Variable from 0.01 to 1.0
Encapsulation
IP40 (IEC 60529)
Humidity (Operating and Storage)
IEC 60068-2-30/24 h 95% relative humidity 25°C to 40°C (77°F to 104°F)
Operating Temperature Range
–15°C to 50°C (5°F to 122°F)
Shock
25 g (IEC 60068-2-27)
Storage Temperature Range
–40°C to 70°C (–40°F to 158°F)
Tripod Mounting
UNC 1/4"-20 (on three sides)
Vibration
2 g (IEC 60068-2-6)
Imaging & Optical
Color palettes
Color palettes (BW, BW inv, Iron, Rain)
Detector Pitch
25 µm
Detector Time Constant
Typical 12 ms
f-number
1.3
Focus
Automatic or manual (built in motor)
Image Frequency
30 Hz
Lens Identification
Automatic
Minimum Focus Distance
0.4 m (1.31 ft.)
Spatial resolution (IFOV)
1.36 mrad
Spectral Range
7.5–13 µm
Video Standard
CVBS (ITU-R-BT.470 PAL/SMPTE 170M NTSC)
Measurement & Analysis
Area
4 boxes with max./min./average/position
External Optics & Windows Correction
Automatic, based on input of optics/window transmission and temperature
Isotherm
1 with above/below/interval
Measurement Corrections
Global and individual object parameters
Measurement Option
Measurement Mask Filter Schedule response: File sending (ftp), email (SMTP)
Optics Transmission Correction
Automatic, based on signals from internal sensors
Reference Temperature
Manually set or captured from any measurement function
Reflected apparent temperature correction
Automatic, based on input of reflected temperature
Set-up Commands
Date/time, Temperature (°C/°F)
Spot Meter
4
Power
External Power Connector Type
2-pole jackable screw terminal
Storage Media
File Formats
Standard JPEG, 16-bit measurement data included
Image Storage Type
Built-in memory for image storage
Check out our other store:
Free US Shipping $100+
Excellent Service